dc.contributor.author |
Rona, Nergiz
|
|
dc.contributor.author |
Yenisey, Murat
|
|
dc.contributor.author |
Küçüktürk, Gökhan
|
|
dc.contributor.author |
Gürün, Hakan
|
|
dc.contributor.author |
Çoğun, Can
|
|
dc.contributor.author |
Esen, Ziya
|
|
dc.date.accessioned |
2020-03-18T08:02:13Z |
|
dc.date.available |
2020-03-18T08:02:13Z |
|
dc.date.issued |
2017-04 |
|
dc.identifier.citation |
Rona, Nergiz...et.al. (2017). "Effect of electrical discharge machining on dental Y-TZP ceramic-resin bonding", Journal Of Prosthodontic Research, Vol.61, No.2, pp.158-167. |
tr_TR |
dc.identifier.issn |
1883-1958 |
|
dc.identifier.uri |
http://hdl.handle.net/20.500.12416/2664 |
|
dc.description.abstract |
Purpose: The study determined (i) the effects of electrical discharge machining (EDM) on the shear-bond strength (SBS) of the bond between luting resin and zirconia ceramic and (ii) zirconia ceramic's flexural strength with the three-point bending (TPB) test.
Methods: Sixty 4.8 mm x 4.8 mm x 3.2 mm zirconia specimens were fabricated and divided into four groups (n = 15): SBG: sandblasted + silane, TSCG: tribochemical silica coated + silane, LTG: Er:YAG laser treated + silane, EDMG: EDM + silane. The specimens were then bonded to a composite block with a dual-cure resin cement and thermal cycled (6000 times) prior to SBS testing. The SBS tests were performed in a universal testing machine. The SBS values were statistically analyzed using ANOVA and Tukey's test. To determine flexural strength, sixty zirconia specimens were prepared and assigned to the same groups (n = 15) mentioned earlier. After surface treatment TPB tests were performed in a universal testing machine (ISO 6872). The flexural strength values were statistically analyzed using ANOVA and Tukey's test (a = 0.05).
Results: The bond strengths for the four test groups (mean SD; MPa) were as follows: SBG (Control), 12.73 +/- 3.41, TSCG, 14.99 +/- 3.14, LTG, 7.93 +/- 2.07, EDMG, 17.05 +/- 2.71. The bond strength of the EDMG was significantly higher than those of the SBG and LTG (p < 0.01). The average flexural strength values for the groups SBG (Control), TSCG, LTG and EDMG were 809.47, 800.47, 679.19 and 695.71 MPa, respectively (p > 0.05).
Conclusions: The EDM process improved the SBS. In addition, there was no significant adverse effect of EDM on the flexural strength of zirconia. |
tr_TR |
dc.language.iso |
eng |
tr_TR |
dc.publisher |
Elsevier Ireland LTD |
tr_TR |
dc.relation.isversionof |
10.1016/j.jpor.2016.07.006 |
tr_TR |
dc.rights |
info:eu-repo/semantics/closedAccess |
tr_TR |
dc.subject |
Zirconia Ceramic |
tr_TR |
dc.subject |
Electrical Discharge Machining |
tr_TR |
dc.subject |
Bonding Strength |
tr_TR |
dc.subject |
Flexural Strength |
tr_TR |
dc.subject |
Graphite Powder |
tr_TR |
dc.title |
Effect of electrical discharge machining on dental Y-TZP ceramic-resin bonding |
tr_TR |
dc.type |
article |
tr_TR |
dc.relation.journal |
Journal Of Prosthodontic Research |
tr_TR |
dc.contributor.authorID |
3837 |
tr_TR |
dc.contributor.authorID |
52373 |
tr_TR |
dc.identifier.volume |
61 |
tr_TR |
dc.identifier.issue |
2 |
tr_TR |
dc.identifier.startpage |
158 |
tr_TR |
dc.identifier.endpage |
167 |
tr_TR |
dc.contributor.department |
Çankaya Üniversitesi, Mühendislik Fakültesi, Mekatronik Mühendisliği; Mazleme Bilimi ve Mühendisliği Bölümü |
tr_TR |