DSpace@Çankaya

Energy and exergy and economic (3E) analysis of a two-stage organic Rankine cycle for single flash geothermal power plant exhaust exergy recovery

Basit öğe kaydını göster

dc.contributor.author Fan, Guangli
dc.contributor.author Gao, Yingjie
dc.contributor.author Ayed, Hamdi
dc.contributor.author Marzouki, Riadh
dc.contributor.author Aryanfar, Yashar
dc.contributor.author Jarad, Fahd
dc.contributor.author Guo, Peixi
dc.date.accessioned 2022-04-08T12:51:42Z
dc.date.available 2022-04-08T12:51:42Z
dc.date.issued 2021-12
dc.identifier.citation Fan, Guangli...et al. (2021). "Energy and exergy and economic (3E) analysis of a two-stage organic Rankine cycle for single flash geothermal power plant exhaust exergy recovery", Case Studies in Thermal Engineering, Vol. 28. tr_TR
dc.identifier.issn 2214-157X
dc.identifier.uri http://hdl.handle.net/20.500.12416/5346
dc.description.abstract A two-stage ORC (Organic Rankine Cycle) is being proposed for the recovery and utilization of low-grade heat from single flash geothermal power plant exhaust flue fluids. The working fluids for two-stage the recovery system are R227ea and R116. The impact of essential design parameters such as inlet temperature of the cycle, ambient temperature, geothermal turbine inlet pressure, geothermal condensation temperature on system performance are investigated using thermodynamic mathematical models regarding energy and exergy efficiencies as the objective function. The addition of the recovery section to the base cycle improves the thermal efficiency from 0.2023 to 0.2178, a 7.66% improvement in this critical metric. Furthermore, the exergy efficiency rises from 0.55044 to 0.5803, representing a 15.04% boost in exergy efficiency. Furthermore, the system's overall output rises from 7690 kW to 9898 kW, representing a substantial gain of 28.71%. The suggested recovery system's cycle has a lower LEC than a single flash geothermal cycle from an economic standpoint. LEC Reduced from $ 0.125 per kilowatt to $ 0.108 per kw, a cost savings. As a result, including a recovery section in the basic single flash geothermal cycle will significantly improve system performance. tr_TR
dc.language.iso eng tr_TR
dc.relation.isversionof 10.1016/j.csite.2021.101554 tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject Geothermal tr_TR
dc.subject Energy tr_TR
dc.subject Exergy tr_TR
dc.subject Organic Rankine Cycle tr_TR
dc.subject Recovery tr_TR
dc.subject ORC tr_TR
dc.title Energy and exergy and economic (3E) analysis of a two-stage organic Rankine cycle for single flash geothermal power plant exhaust exergy recovery tr_TR
dc.type article tr_TR
dc.relation.journal Case Studies in Thermal Engineering tr_TR
dc.contributor.authorID 234808 tr_TR
dc.identifier.volume 28 tr_TR
dc.contributor.department Çankaya Üniversitesi, Fen - Edebiyat Fakültesi, Matematik Bölümü tr_TR