DSpace@Çankaya

Measuring fluid flow and heat output in seafloor hydrothermal environments

Basit öğe kaydını göster

dc.contributor.author Germanovich, Leonid N.
dc.contributor.author Hurt, Robert S.
dc.contributor.author Smith, Joshua E.
dc.contributor.author Genç, Gence
dc.contributor.author Lowell, Robert P
dc.date.accessioned 2022-06-17T12:18:12Z
dc.date.available 2022-06-17T12:18:12Z
dc.date.issued 2015-12-01
dc.identifier.citation Germanovich, Leonid N...et al (2015). "Measuring fluid flow and heat output in seafloor hydrothermal environments", Journal of Geophysical Research: Solid Eart, Vol. 120, No. 12, pp. 8031-8055. tr_TR
dc.identifier.issn 2169-9313
dc.identifier.uri http://hdl.handle.net/20.500.12416/5657
dc.description.abstract We review techniques for measuring fluid flow and advective heat output from seafloor hydrothermal systems and describe new anemometer and turbine flowmeter devices we have designed, built, calibrated, and tested. These devices allow measuring fluid velocity at high- and low-temperature focused and diffuse discharge sites at oceanic spreading centers. The devices perform at ocean floor depths and black smoker temperatures and can be used to measure flow rates ranging over 2 orders of magnitude. Flow velocity is determined from the rotation rate of the rotor blades or paddle assembly. These devices have an open bearing design that eliminates clogging by particles or chemical precipitates as the fluid passes by the rotors. The devices are compact and lightweight enough for deployment from either an occupied or remotely operated submersible. The measured flow rates can be used in conjunction with vent temperature or geochemical measurements to obtain heat outputs or geochemical fluxes from both vent chimneys and diffuse flow regions. The devices have been tested on 30 Alvin dives on the Juan de Fuca Ridge and 3 Jason dives on the East Pacific Rise (EPR). We measured an anomalously low entrainment coefficient (0.064) and report 104 new measurements over a wide range of discharge temperatures (5°-363°C), velocities (2-199 cm/s), and depths (1517-2511 m). These include the first advective heat output measurements at the High Rise vent field and the first direct fluid flow measurement at Middle Valley. Our data suggest that black smoker heat output at the Main Endeavour vent field may have declined since 1994 and that after the 2005-2006 eruption, the high-temperature advective flow at the EPR 9°50′N field may have become more channelized, predominately discharging through the Bio 9 structure. We also report 16 measurements on 10 Alvin dives and 2 Jason dives with flow meters that predate devices described in this work and were used in the process of their development. This includes the first advective measurements in the Lau Basin and at the EPR 9°39.5′N. We discuss potential error sources and how they may affect the accuracy of measurements by our devices and other devices. In particular, we use the turbulent plume theory to evaluate the effect of entrainment of ambient seawater. ©2015. American Geophysical Union. All Rights Reserved. tr_TR
dc.language.iso eng tr_TR
dc.relation.isversionof 10.1002/2015JB012245 tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject Fluid Flow tr_TR
dc.subject Heat Output tr_TR
dc.subject Hydrothermal Systems tr_TR
dc.subject Instrumentation tr_TR
dc.subject Mid-Ocean Ridges tr_TR
dc.title Measuring fluid flow and heat output in seafloor hydrothermal environments tr_TR
dc.type article tr_TR
dc.relation.journal Journal of Geophysical Research: Solid Earth tr_TR
dc.identifier.volume 120 tr_TR
dc.identifier.issue 12 tr_TR
dc.identifier.startpage 8031 tr_TR
dc.identifier.endpage 8055 tr_TR
dc.contributor.department Çankaya Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü tr_TR


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster