DSpace@Çankaya

Dynamic shear force amplification in regular frame-wall systems

Basit öğe kaydını göster

dc.contributor.author Kazaz, İlker
dc.contributor.author Gülkan, Polat
dc.date.accessioned 2020-04-16T21:21:38Z
dc.date.available 2020-04-16T21:21:38Z
dc.date.issued 2016-02-10
dc.identifier.citation Kazaz, Ilker; Gulkan, Polat, "Dynamic shear force amplification in regular frame-wall systems", Structural Design of Tall and Special Buildings, Vol. 25, No. 2, pp. 112-135, (2016). tr_TR
dc.identifier.issn 1541-7794
dc.identifier.issn 1541-7808
dc.identifier.uri http://hdl.handle.net/20.500.12416/3254
dc.description.abstract A parametric study is conducted to investigate the dynamic shear amplification factor (DAF) in low-to-mid-rise frame-wall systems in which the reinforcement curtailment along the height matches the required code strength. The level of frame-wall interaction is varied by changing the wall index, defined as the ratio of the total wall area to the floor plan area, in a generic frame-wall system, and its correlation with the DAF is investigated. Wall index values ranging in the 0.2% to 2% interval are selected. Walls with lengths of 3m, 5m and 8m are used in the design of model buildings of 4, 8 and 12 stories. Shear-flexure beam continuum formulation is used in design and modeling. The global behavior is analyzed using nonlinear response history procedure using spectrum compatible ground motions. It is found that the primary source of amplification is the level of inelastic demand on the system. Walls designed for code-specified force reduction factor R=6 experienced an average base shear force amplification in the order of 1.64 with standard deviation of 0.19 with respect to design shear force. Amplification diminishes with decreasing R. An expression for the dynamic amplification factor as a function of the number of stories and force reduction factor R is proposed. Copyright (C) 2015 John Wiley & Sons, Ltd. tr_TR
dc.language.iso eng tr_TR
dc.publisher Wiley tr_TR
dc.relation.isversionof 10.1002/tal.1231 tr_TR
dc.rights info:eu-repo/semantics/closedAccess tr_TR
dc.subject Dynamic Amplification Factor tr_TR
dc.subject Shear Wall tr_TR
dc.subject Frame-Wall tr_TR
dc.subject Dual System tr_TR
dc.subject Behavior Factor tr_TR
dc.subject Shear Envelope tr_TR
dc.title Dynamic shear force amplification in regular frame-wall systems tr_TR
dc.type article tr_TR
dc.relation.journal Structural Design of Tall and Special Buildings tr_TR
dc.contributor.authorID 5743 tr_TR
dc.identifier.volume 25 tr_TR
dc.identifier.issue 2 tr_TR
dc.identifier.startpage 112 tr_TR
dc.identifier.endpage 135 tr_TR
dc.contributor.department Çankaya Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü tr_TR


Bu öğenin dosyaları:

Dosyalar Boyut Biçim Göster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster