DSpace Repository

Experimental investigation of damaged square short RC columns with low slenderness retrofitted by CFRP strips under axial load

Show simple item record

dc.contributor.author Ghoroubi, Rahim
dc.contributor.author Mercimek, Ömer
dc.contributor.author Özdemir, Anıl
dc.contributor.author Anıl, Özgür
dc.date.accessioned 2021-06-16T10:25:58Z
dc.date.available 2021-06-16T10:25:58Z
dc.date.issued 2020-12
dc.identifier.citation Ghoroubi, Rahim...at all (2020). "Experimental investigation of damaged square short RC columns with low slenderness retrofitted by CFRP strips under axial load", Structures, Vol. 28, pp. 170-180. tr_TR
dc.identifier.issn 2352-0124
dc.identifier.uri http://hdl.handle.net/20.500.12416/4805
dc.description.abstract The aim of this study is to develop the retrofitting details, which will increase axial ultimate load capacity, stiffness, displacement ductility ratios, and energy dissipation capacities of short reinforced concrete (RC) low slenderness columns to avoid adverse effects on earthquake performance. The main variables examined in the experimental study are the Carbon Reinforced Fiber Polymer (CFRP) strip width used for retrofitting, the distance between CFRP strips, the use of the anchor at the overlap zone in the CFRP strips, and the placement of the CFRP strips horizontally or vertically to the column axis. For these purposes, eleven square short RC columns with a dimension of 150x150x500 mm (with low slenderness ratio: lambda = 11.5) were produced. The columns were damaged up to 50% of their axial load carrying capacity, then retrofitted with CFRP strips in different ways. The short RC columns with low slenderness ratio were tested under monotonic axial loading until they failure. By obtaining the axial load-displacement graphs of the test specimens, the ultimate axial load capacity, initial stiffness value, displacement-ductility ratios, and energy dissipation capacities are calculated and interpreted. It has been found that the most successful retrofitting detail is obtained when CFRP strips are placed perpendicular to the column axis, and CFRP fan-type anchors are used in the strip overlap region. tr_TR
dc.language.iso eng tr_TR
dc.relation.isversionof 10.1016/j.istruc.2020.08.068 tr_TR
dc.rights info:eu-repo/semantics/closedAccess tr_TR
dc.subject RC Short Column tr_TR
dc.subject CFRP tr_TR
dc.subject Retrofitting tr_TR
dc.subject Axial Load tr_TR
dc.subject Ductility and Energy Dissipation tr_TR
dc.title Experimental investigation of damaged square short RC columns with low slenderness retrofitted by CFRP strips under axial load tr_TR
dc.type article tr_TR
dc.relation.journal Structures tr_TR
dc.contributor.authorID 30604 tr_TR
dc.identifier.startpage 170 tr_TR
dc.identifier.endpage 180 tr_TR
dc.contributor.department Çankaya Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü tr_TR


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record