DSpace@Çankaya

Hydrodynamic analysis of a heat exchanger with crosscut twisted tapes and filled with thermal oil-based SWCNT nanofluid: applying ANN for prediction of objective parameters

Basit öğe kaydını göster

dc.contributor.author Abu-Hamdeh, Nidal H.
dc.contributor.author Almitani, Khalid H.
dc.contributor.author Gari, Abdullatif A.
dc.contributor.author Alimoradi, Ashkan
dc.contributor.author Ahmadian, Ali
dc.contributor.author Baleanu, Dumitru
dc.date.accessioned 2022-05-20T12:03:23Z
dc.date.available 2022-05-20T12:03:23Z
dc.date.issued 2021-08
dc.identifier.citation Abu-Hamdeh, Nidal H...et al. (2021). "Hydrodynamic analysis of a heat exchanger with crosscut twisted tapes and filled with thermal oil-based SWCNT nanofluid: applying ANN for prediction of objective parameters", Journal of Thermal Analysis and Calorimetry, Vol. 145, No. 4, pp. 2163-2176. tr_TR
dc.identifier.issn 1388-6150
dc.identifier.uri http://hdl.handle.net/20.500.12416/5530
dc.description.abstract Present study investigates hydrodynamic analysis of heat exchanger with crosscut twisted tapes and filled with thermal oil-based SWCNT nanofluid (NF). SIMPLE algorithm and FVM method are used. The heat transfer fluid enters the test section at Tin = 300 K in different flow velocities, which are related with Reynolds numbers 5000, 10,000, 15,000 and 20,000. For ensuring that the input flow to test section is always fully developed, the input part to length 2L is considered. It is also intended to ensure that the flow does not return to test section of the exit section of length L. Also, the test section has the constant temperature of Ts = 400 K. Different geometrical parameters of twisted tapes in heat exchanger are studied. The optimization is carried out due to fulfill the highest performance evaluation criterion (PEC index). Based on results, usage of twisted tapes has a sharp impact on thermal and hydraulic characteristics of heat exchanger and leading to swirling motion, which improve the heat transfer coefficient and augment the pressure drop (ΔP). Besides, usage of simple model is more efficient than crosscut model. Also, it is understood that the PEC index values always are more than 1.11, which means that employment of these turbulators is effective and positive with thermal–hydraulic viewpoint. The simple model (Case K and N = 8) is introduced as the most optimum model in this paper, and its PEC values for system filled with NF in ϕ = 0.8% at Re = 5000, 10,000, 15,000 and 20,000 are 1.37, 1.59, 1.78 and 1.93, respectively. The application of machine learning methods showed that the output parameters in the simulation of heat exchangers are well predicted. The accuracy of the developed neural network was such that the maximum error was below 1%. © 2021, Akadémiai Kiadó, Budapest, Hungary. tr_TR
dc.language.iso eng tr_TR
dc.relation.isversionof 10.1007/s10973-020-10521-4 tr_TR
dc.rights info:eu-repo/semantics/closedAccess tr_TR
dc.subject ANN tr_TR
dc.subject Crosscut Tape tr_TR
dc.subject Heat Exchanger tr_TR
dc.subject Nanofluid tr_TR
dc.subject Thermal–Hydraulic tr_TR
dc.subject Twisted Tape tr_TR
dc.title Hydrodynamic analysis of a heat exchanger with crosscut twisted tapes and filled with thermal oil-based SWCNT nanofluid: applying ANN for prediction of objective parameters tr_TR
dc.type article tr_TR
dc.relation.journal Journal of Thermal Analysis and Calorimetry tr_TR
dc.contributor.authorID 56389 tr_TR
dc.identifier.volume 145 tr_TR
dc.identifier.issue 4 tr_TR
dc.identifier.startpage 2163 tr_TR
dc.identifier.endpage 2176 tr_TR
dc.contributor.department Çankaya Üniversitesi, Fen - Edebiyat Fakültesi, Matematik Bölümü tr_TR


Bu öğenin dosyaları:

Dosyalar Boyut Biçim Göster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster