DSpace Repository

Unbalanced Operation in Transformers Used in PV Plants

Show simple item record

dc.contributor.author Yükselen, Emir
dc.contributor.author Iskender, Ires
dc.date.accessioned 2024-05-14T07:49:35Z
dc.date.available 2024-05-14T07:49:35Z
dc.date.issued 2022-12
dc.identifier.citation Yükselen, Emir; Iskender, Ires (2022). "Unbalanced Operation in Transformers Used in PV Plants", International Journal of Renewable Energy Research, Vol.12, No.4, pp.2200-2205. tr_TR
dc.identifier.issn 13090127
dc.identifier.uri http://hdl.handle.net/20.500.12416/8241
dc.description.abstract Renewable energy has become the most preferred energy sources today due to its environmental and economic advantages. One of the renewable energies is solar energy, in which Photovoltaic (PV) cells are used to convert solar energy into electrical energy. In this respect, Solar Power Plant (SPP) is one of the popular renewable energy sources and the integration of such power sources into electricity grids has been increasing in recent years. Transformers are one of the largest capital investments in solar power generation and the way they work is different from transformers used in a substation. Therefore, failure of transformers has significant economic effects on electrical networks. The PV type transformer is powered by the inverter and needs to be customized to work with every system. Consequently, the safe operation and reliability of this type of transformer is critical to the sustainability of the electrical grid. Consequently, identifying the probability of failure as a preventative action for grid protection is critical and should be addressed to improve electrical system reliability. The main purpose of this study is to analyze the effects of the unbalanced operation of the inverter on the performance of the special type transformer used in the PV plant and to show how the inverter operation can affect the operation of the transformer. tr_TR
dc.language.iso eng tr_TR
dc.relation.isversionof 10.20508/ijrer.v12i4.13596.g8586 tr_TR
dc.rights info:eu-repo/semantics/closedAccess tr_TR
dc.subject Finite Element Method (Fem) tr_TR
dc.subject Photovoltaic (Pv) tr_TR
dc.subject Solar Power Plant (Spp) tr_TR
dc.subject Transformer tr_TR
dc.subject Unbalance Condition tr_TR
dc.title Unbalanced Operation in Transformers Used in PV Plants tr_TR
dc.type article tr_TR
dc.relation.journal International Journal of Renewable Energy Research tr_TR
dc.contributor.authorID 133746 tr_TR
dc.identifier.volume 12 tr_TR
dc.identifier.issue 4 tr_TR
dc.identifier.startpage 2200 tr_TR
dc.identifier.endpage 2205 tr_TR
dc.contributor.department Çankaya Üniversitesi, Mühendislik Fakültesi, Elektrik Elektronik Mühendisliği Bölümü tr_TR