DSpace@Çankaya

Combined application of continuous wavelet transform-zero crossing technique in the simultaneous spectrophotometric determination of perindopril and indapamid in tablets

Basit öğe kaydını göster

dc.contributor.author Pektaş, Gözde
dc.contributor.author Dinç, Erdal
dc.contributor.author Baleanu, Dumitru
dc.date.accessioned 2016-05-11T11:45:16Z
dc.date.available 2016-05-11T11:45:16Z
dc.date.issued 2009
dc.identifier.citation Pektaş, G., Dinç, E., Baleanu, D. (2009). Combined application of continuous wavelet transform-zero crossing technique in the simultaneous spectrophotometric determination of perindopril and indapamid in tablets. Quimica Nova, 32(6), 1416-1421. tr_TR
dc.identifier.issn 0100-4042
dc.identifier.uri http://hdl.handle.net/20.500.12416/989
dc.description.abstract Signal processing methods based on the combined use of the continuous wavelet transform (CWT) and zero-crossing technique were applied to the simultaneous spectrophotometric determination of perindopril (PER) and indapamide (IND) in tablets. These signal processing methods do not require any priory separation step. Initially, various wavelet families were tested to identify the optimum signal processing giving the best recovery results. From this procedure, the Haar and Biorthogonal 1.5 continuous wavelet transform (HAAR-CWT and BIOR 1.5-CWT, respectively) were found suitable for the analysis of the related compounds. After transformation of the absorbance vectors by using HAAR-CWT and BIOR 1.5-CWT, the CWT-coefficients were drawn as a graph versus wavelength and then the HAAR-CWT and BIOR 1.5-CWT spectra were obtained. Calibration graphs for PER and IND were obtained by measuring the CWT amplitudes at 231.1 and 291.0 rim in the HAAR-CWT spectra and at 228.5 and 246.8 nm in BIOR 1.5-CWT spectra. respectively. In order to compare the performance of HAAR-CWT and BIOR 1.5-CWT approaches, derivative spectrophotometric (DS) method and HPLC as comparison methods, were applied to the PER-IND samples. In this DS method, first derivative absorbance values at 221.6 for PER and 282.7 nm for IND were used to obtain the calibration graphs. The validation of the CWT and DS signal processing methods was carried out by using the recovery study and standard addition technique. In the following step, these methods were Successfully applied to the commercial tablets containing PER and IND compounds and good accuracy and precision were reported for the experimental results obtained by all proposed signal processing methods tr_TR
dc.language.iso eng tr_TR
dc.publisher Soc Brasileira Quimica tr_TR
dc.rights info:eu-repo/semantics/openAccess
dc.subject Continuous Wavelet Transform tr_TR
dc.subject Zero Crossing Technique tr_TR
dc.subject Perindopril tr_TR
dc.title Combined application of continuous wavelet transform-zero crossing technique in the simultaneous spectrophotometric determination of perindopril and indapamid in tablets tr_TR
dc.type article tr_TR
dc.relation.journal Quimica Nova tr_TR
dc.contributor.authorID 197407 tr_TR
dc.contributor.authorID 6981 tr_TR
dc.identifier.volume 32 tr_TR
dc.identifier.issue 6 tr_TR
dc.identifier.startpage 1416 tr_TR
dc.identifier.endpage 1421 tr_TR
dc.contributor.department Çankaya Üniversitesi, Fen Edebiyat Fakültesi, Matematik Bilgisayar Bölümü tr_TR


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster